Automation Air Bubble Remove Machine
Bubble Remove Machine
1、Application:
This machine is used to remove the bubble which is caused after Laminating
The LCM with Polarizer or other Panels.,and Pressure Re-laminating,
Size:600X900mm/800X1200mm/ 900x1200mm/ 1000×1200mm Optional,Also
Accept CUSTOMIZED.
2、Parameter
No. | Item | Spec. |
2.1 | Available Sizes | Available size :
Inner Diameter 600X900mm/800X1200mm/ 900x1200mm/ 1000×1200mm Optional |
2.2 | Available Types | 1)Polaroid Bubble Remove;
2)OCA Bubble Remove; 3)PET Bubble Remove; 4)Other Products Bubble Remove; |
3、Equipment Characteristic
No. | Item | Spec. |
3.1 | process flows | Set temperature,pressure,time,etc.on operation interface
1)Open Cavity door and put the product inside; 2)Inter automatic mode,close the cavity door,start work; Bubble remove finished,equipment automatically open the door,take out the product and next steps; |
3.2 | Output | can be Set according Product Process |
3.3 | equipment failure rate | ≤0.01% |
4、Equipment Whole and Unit Parameter
NO. | Item | Spec. |
4.1 | Supply-demand Power | AC380V three-phase 50-60Hz ,15KW |
4.2 | air compression | 1)Weasand color:Black;
2)Weasand Diameter:¢8mm; 3)Working Pressure:0.5-0.8Mpa; |
4.3 | Equipment Color | The Frame With Stainless Steel Mirror Plate Surface |
4.4 | Weight | About1.5-3.5T (in kind prevail) |
4.5 | Dimension | L2800*W1980*H2200mm (in kind prevail) |
4.6 | Operate Interface Unit | Touch Screen Interface Language:Chinese
Parameter Set Interface:Can set and display the parameter on Touch panel; 1)Automatic Mode Interface; 2)Manual Mode Interface; 3)Abnormal Alarm Interface; 4)Touch Screen Code Lock(Optional); |
4.7 | Heating Unit | 1)Temperature Range:RT-100℃;
2)Temperature Precision:±1℃ to 3℃; 3)Thermocouple:K type; 4)Heating mode:Constant Heat ; 5)Over temperature Protection:over temperature then stop heating. |
4.8 | Pressure Cavity Unit | 1)Limiting Pressure:2Mpa;
2)Work Temperature:0.1-0.85Mpa; 3)Cavity Materials:SUS304; 4)Manufacturing Standard:1:3 National Standard; 5)Effective Volume :Optional; 6)Overpressure Protection:Overpressure then stop air in,the Safety valve automatic Air Leakage; 7)Cavity Detection Unit:Provincial Quality inspection; Bureau of quality supervision; 8)Drawing Providing Unit:Provincial institute of chemical machinery research institute; 9)pressure Precision:±0.01Mpa; |
4.9 | Automatic Quick Door-Open Unit | 1)Door Switch Mode:Pneumatic Type Automatic ON/OFF;
Safety Interlocking:Patent Interlocking Open/Close Door and outtake/intake process interlocking; |
4.10 | Fan Round Fan Unit | 1)Drive Mode:Electromagnetic Type Dynamo Direct Drive;
2)Fan Blade Type:Turbine Fan Blade; 3)Operating Life:10W-15W hours; |